Medical Waste Incinerator, 50 to 60 Kg/hr Support Health Sector Support Project Point of Installation (Hospitals) Moi Voi, Makindu, Maragua, Eldama Ravine and Isiolo District Hospitals 1. General Description Supply, delivery, installation and commissioning of a medical waste incinerator suitable for disposal of Medical, General and Pathological waste in a safe and clean environment. The unit shall consist of two chambers and operate on the principal of controlled air and temperature. The unit shall consist a particulate remover (scrubbers) as stipulated in waste management regulations, 2006 (Legal notice NO. 121 of 29th September, 2006). The Unit shall be fully automatic and controlled by an automatic electronic controlled system except loading system which shall be manual. The unit shall be capable of incinerating between 50 to 60 kg of solid medical waste per hour. It shall be constructed from mild or aluminized steel lined with refractory material. Main unit Application For incineration, general and pathological Capacity 50 C 60 kg/h burn rate Type Two combustion chambers type; primary and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time Minimum 8 hours daily Operating temperature From 850 0C to 1200 0C, Automatic controlled Residual Ash 5 to 10% 3.2 Primary Chamber Construction Constructed from heavy duty mild or aluminized steel Or equal and approved equivalent Insulation material …
combustion
Incinerator Primary Combustion Chamber
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce. Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with other disposal methods. Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Website: www.hiclover.com Email: [email protected] Email: [email protected]
Incinerator Primary Combustion Chamber
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce. Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with other disposal methods. Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel: +86-25-8461 0201 Website: www.hiclover.com Email: [email protected] Email: [email protected]
Refractory constructions incinerator
* Burning Rate (50-120kg/hour) * Minimum Operating Temperature (850°ϲ(Primary combustion) * Maximum Operating Temperature (1450°ϲ(Afterburner chamber) * Secondary Burning Capacity (Compulsory) * Density Insulation (20mm high) * Refractory Casting (Minimum 65mm) * Heavy duty refracting lining to withstand (1500°ϲ) * Average burn out time: Maximum (3.0 hours) * Fuel Type (Diesel) * Fuel Consumption in L/hr: (7.5 to 9) * Residence time in secondary chamber (2 sec.) * Residue ash post 100kg (Max. 3.8kg) * Installation period (Maximum 7days) Type : Refractory constructions Steel Structure 400+ Silica board + Fire Brick and Castable between Size : Outside – W 740 x L 1112 x H 790 / Inside – W 400 x L 800 x H 560 (mm) Fire load of Combustion volume : 0.18 m3 Fire table area : 0.32 m2 Material : SS400 x 6.0T, Silica Board, Fire Brick (SK-36), Castable (HACT-160) Temperature : 700 ~ 900 ℃ Residual gas combustion in secondary chambers : ≥ 2sec Input door size : W 200 x H 200 (mm) Ash door size : W 300 x H 400 (mm) Type : Refractory constructions …
50-100-150-200 Kgs per Hour Solid Waste Incinerator Model TS150 PLC 1570Liters Chamber
Waste Incinerator Model TS150 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 sets …
Pre-assembled containerized type waste incinerator
Pre-assembled, containerized type Burning rate: 100 – 120kg / hour medical waste incinerator Minimum operating temperature: 8500c (Primary combustion) Maximum operating temperature: 14500c (afterburner chamber) …
medical incinerator
medical incinerator is incineration equipment for the waste from hospital, clinic,laboratory or other related department. the medical waste including plastic material like syringe, Infusion set, …
hospital incinerator
Principle of the hospital incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc.The main body is …
Incinérateur avec Capacité de destruction en poids: 60 Kg / h.
Capacité de destruction en poids: 60 Kg / h. Il doit pouvoir fonctionner au moins 10 heures / jour Cet incinérateur doit être capable de …
medical waste incinerator
medical waste incinerator is one type waste incinerator for hospital medical waste and the difference is the dual combustion chamber design to make it enviromental …