Showing: 2231 - 2240 of 2,401 RESULTS

Incinerator Requirements

The requirements for a unit are as follows: 1. chemical agents to be utilized: • 10% heptyl (unsymmetrical dimethylhydrazine) water solution, • heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m³ concentration, • 10% azotic (nitric) acid water solution, • azotic (nitric) acid vapour with concentration up to 1.1 kg/m³; 2. neutralization method: thermal decomposition; 3. neutralization temperature: +800˚C to +1200˚C; 4. performance: • vapour capacity: 70 to 200 m³/h, • water solution capacity: 50 to 500 l/h; 5. inlet pressure: up to 2 bars; 6. automatic control system; …